WUHAN FUTE LITHIUM BATTERY CO.LTD-ER34615
3.6V SIZE D LITHIUM BATTERY ER34615
TL-5930 TL-4930 LS33600 TL-2300 XL -205F XL -200F REPLACEMENT
GPS- NIGHT VISION 每EQUIPMENT- MEDICAL EQUIPMENT
1. Model NO. ㄩ ER34615H
2. Specification
1) Nominal voltage ㄩ 3.6V
2) Nominal capacity ㄩ 16500mAh(2mA / 2.0V)
3) Nominal discharge current ㄩ 2mA(1500 次 )
4) Rapid discharge ㄩ 60mA(56 次 )
5) Discharge end-voltage ㄩ 2.0V
6) Operating voltage ㄩ 3.5V(330 次 , in 5s)
7) Max constant discharge current ㄩ 230mA
8 ㄘ Max. pulse current ㄩ 400mA
9) Ambient temperature range ㄩ -55~ + 85 ⊥
10) Storage life ㄩ ≡ 10 years, Yearly self-discharge ≒ 1%
3. Appearance & Dimension/Weight
1) Appearance: cylinder shape
2) Max dimension : 耳 34.0mm ℅h 61.5mm
3) Max weight: 102g
4. Performance Testing
Unless otherwise request , all tests are carried out in ambient temperature 20㊣ 5 ⊥ .
Tests should be made within 45 days after receipt of the batteries.
Item |
Measuring Procedure |
Standard |
1.Appearance |
Visual check |
Clean, unscratched and clearly labeled |
2.Dimenaions |
Measured by calipers with precision of 0.02mm |
耳 34.0℅ 61.5mm max |
3.Weight |
Weighed by balance with precision of 0.1g |
102g max |
4.Open-circuit voltage |
Measure by volt-meter with precision of 0.01V |
≡ 3.65V |
5.Operating voltage |
Measure by volt-meter with precision of 0.01V, connecting an impedance of 200 次 in series, Reaching the target voltage in 5 seconds. |
≡ 3.45V |
6.Nominal discharge |
1500 次 ,20 ㊣ 2 ⊥ , Constant discharge to 2.0V. |
≡ 16.5Ah |
7.Rapid discharge |
30 次 ,20 ㊣ 2 ⊥ , Constant discharge to 2.0V. |
≡ 9.0Ah |
8. Discharge at high temperature |
Put battery in constant ambient temperature of 55 ㊣ 2 ⊥ for 16 hours, discharge at 200 次 to 2.0V/cell. |
≡ 12.5Ah |
9.Discharge at low temperature |
Put battery in constant ambient temperature of -40 ㊣ 2 ⊥ for 16 hours, discharge at 680 次 to 2.0V/cell |
≡ 6.5Ah |
10.Charge |
Prohibited |
Prohibited |
11.Over-discharge |
Prohibited |
Prohibited |
12.Self discharge |
Store the batteries at constant temperature of 20 ㊣ 5 ⊥ , Measure the nominal capacity yearly for 10 years. |
≒ 1% |
Examination procedure & standard
Unless otherwise request , all tests are carried out in ambient temperature 20㊣ 5 ⊥ .
Tests should be made within 45 days after receipt of the batteries. |